The State Well Codes database stores state standards for the construction of private water wells.
Included in the database is state-specific information on various codes related to well construction and siting. To find information on your state or other states, use the searchable database below.
Please note that this database is intended as a guide and occasionally standards change. WSC updates the database periodically, but we encourage you to obtain a full list of state well codes from your state environmental agency or contact the wellcare® Hotline for assistance.
If you have questions about the database, corrections or updates, please contact Charlene Bean.
Please click on the State Name in the list below for well code information. If you would like to alphabetize the table, click on the column name in blue.
State | Category | Subcategory | Standard Description |
---|---|---|---|
Michigan | Location | Dry Well |
50 ft. |
Michigan | Location | Cesspool |
50 ft. |
Michigan | Location | Buried Sewer |
50 ft. |
Michigan | Location | Buried Gravity Flow Sewer (SCH 40 PVC) |
10 ft. |
Michigan | Location | Building, Pump Room |
3 ft. |
Michigan | Location | Barnyard |
50 ft. |
Michigan | Location | Active Work Area Of Landfill |
800 ft. |
Michigan | Licensing | Licensing - General |
All well drilling contractors and pump installer, shall have a certificate of registration. |
Michigan | Identification | Identification - General |
Piping to be clearly marked with identifying information. |
Michigan | Grout | Grout - General |
All wells shall be grouted with either neat cement or bentonite grout from bottom to top in one continuous operation. Must be in compliance with or surpass ANSI/NSF standard 14, 60, or 61, ASTM specification C 150, or section 10 of API |
Michigan | Grout | Concrete |
Conform to AWWA A100 Section 7 w/ no>6 gal. of water per pack cement for > 1.5 in openings. Bentonite: same as neat cement or dry granular bentonite shall be maintained around the casing as it is being driven. |
Michigan | Vents | Vents - General |
Shall be screened, pointed downward and terminate not less than 12 inches above the ground or above the floor, and not less than 24 inches above any known flood level. Screening shall not be less than 20-mesh per inch and not more than 30-mesh per inch. Screening shall not reduce vent open area by more than 50%. |
Michigan | Seals | Seals - General |
To be watertight, vermin-proof, & provide venting. |
Michigan | Screens | Screens - General |
Where installed on a casing that is less than 4 inches inside diameter, shall be telescoped and removable. |
Michigan | Pressure Tanks | Pressure Tanks - General |
Shall be installed in an approved pump house, well house, crawlspace, basement offset or basement. Materials must be in compliance with or surpass ANSI/NSF standard 14, 60, or 61, ASTM specification C 150, or section 10 of API specification 10. |
Michigan | Pressure Relief Valve | Pressure Relief Valve - General |
Required when pressure of the pump can exceed the working pressure of the pressure tank. |
Michigan | Plumbness & Alignment | Plumbness & Alignment - General |
Well shall be sufficiently straight and vertical to allow normal installation and operation of the pump. |
Michigan | Pitless Adapters | Pitless Adapters - General |
Must be approved by the department. |
Michigan | Packers | Packers - General |
Shall not be used to suspend grout above an open annular space. Lead packers, lead plugs, or lead wool shall not be used as a well component. |
Michigan | Location | Wastewater Treatment Facility |
300 ft. |
Michigan | Location | Surface Water Body |
10 ft. |
Michigan | Location | Subsurface Disposal Field |
50 ft. |
Michigan | Location | Storage Tank Systems |
50 ft. |
Michigan | Location | Sewers (Extra-Heavy Cast Iron Pipe, Etc.) |
50 ft. |
Michigan | Location | Sewage Pump Chamber |
50 ft. |
Michigan | Location | Septic Tank |
50 ft. |
Michigan | Location | Seepage Pit |
50 ft. |
Minnesota | Electrical Connection | Electrical Connection - General |
Must enter a casing, cap, cover, or pump base a minimum of 12 inches above the established ground surface except for a well or boring completed at-grade, wires above ground surface must be contained within conduit or casing, must be made watertight and vermin-proof with fittings installed according to MN Statutes section 326B.35 or caulk meeting ANSI/NSF 14-2003 or 61-2003e. |
Minnesota | Disinfection | Disinfection - General |
50 ppm free chlorine in all parts of well w/2 hour contact time. For repair, 200 ppm free chlorine during course of repair. Chlorine materials must meet the ANSI/NSF 60-2000e or USEPA (FIFRA), section 3(c)(7)(A), as an antimicrobial pesticide for use in potable water. |
Minnesota | Development | Development - General |
New well must not produce a sustained quantity of more than 5 mg/L of sand, or more than 200 mg/L of silt and clay except when geological conditions preclude meeting the standard, and the well owner, licensee, and commissioner agree to accept the sediment in a stipulated agreement. Development must not occur until 48 hours after cement grout is placed. |
Minnesota | Casing | Steel |
ASTM Standard A53/A53M-04a; A589-96 (2001), Types I, II, and III; or API Standard 5L-04. Must have the minimum weights and thicknesses specified in the table in 4725.2350 subpart 2. |
Minnesota | Casing | Plastic |
ASTM F480-02 except flush threaded polyvinyl chloride casing must not be used except for a monitoring well or environmental bore hole; and just withstand internal pressure of 200 psi. Plastic casing must not be used as an outside casing in a water-supply well cased more than five feet into limestone or dolomite bedrock, except that an inner plastic casing may be installed entirely inside an outer steel casing in accordance with part 4725.2250, subpart 8. |
Minnesota | Casing | Joints |
Must be watertight and comply with casing standards in part 4725.2350, 4725.2550, or 4725.6650. Threaded joints just have recessed couplings, reamed and drifter couplings, or other couplings that match the design, taper, and thread type of the casing. Thread must not be exposed on pipe when casing is joined. Welded casing, except where approved welding coupling is used, must have beveled joints. Weld must extend the full circumference of the casing and must completely fill the bevel. Welding couplings must be made of material equivalent to casing. Upper and lower welds must extend the full circumference of the casing, and completely fill the gap between the coupling and casing. Welding the casing to the inside of the coupling is prohibited. To connect steel pitless unit or screen to plastic casing, may use fitting or couplings with socket dimensions meeting requirements of ASTM F480-02, and have a water pressure rating of at least 200 psi; schedule 40, slip x internal thread fittings, 4 inch and smaller meeting the requirements of ASTM D2466-02; or schedule 40, slip x internal thread fittings and slip x external thread fittings, 5 inch diameter meeting the requirements of ASTM D2466-02. |
Minnesota | Casing | Casing - General |
Must be cased to a depth of at least 15 ft from the established ground surface. Must be watertight throughout length with threaded, solvent-welded, welded joints - New casing required. Casing must be marked by MFG. All plastic casings, couplings, components, and related joining materials including solvents, cements, or primers used in the construction of a well or boring must conform with the requirements of ANSI/NSF Standard 61-2003e or the health effects portion of ANSI/NSF Standard 14-2003 and be tested as conforming by an agency certified by the ANSI. Conformance to the ANSI/NSF standard must be coded, stamped, or marked on the casings, couplings, components, and related joining materials including solvents, cements, or primers. |
Minnesota | Caps | Caps - General |
Weatherproof and made of metal or plastic installed on inner casing with thickness comparable to casing requirements. Must consist of: overlapping cover or cap; threaded plug, cover or plate; sanitary seal or plug with 1pc top plate, compression gasket, and non corrodible draw bolt. If connection is made to casing less than 12 inches above ground surface, must be watertight, vermin-proof, and be made at or above frost line. |
Minnesota | Abandonment | Abandonment - General |
Wells and borings must be sealed from bottom to surface. |
Minnesota | Location | Cesspool, Seepage Pit, Leaching Pit, Dry Well |
Must be 75 ft. Distance is doubled to 150 ft from a sensitive well. A "Sensitive water-supply well" is defined as a water-supply well with less than 50 feet of watertight casing where the casing does not penetrate a confining layer or multiple layers of confining materials with an aggregate thickness of 10 feet or more. |
Minnesota | Location | Buried Sewer |
Must be 50 ft. from buried sewer that serves as collector, is open jointed, or built with unapproved materials. Includes floor drain, grate or trough connected to a buried sewer. 20 ft from buried sewer serving one building, or two or less single-family residences, constructed of cast iron or plastic pipe that has been successfully pressure-tested. |
Minnesota | Location | Building Projections |
3 ft. |
Minnesota | Location | Animal or Poultry Building |
50 ft. Distance is doubled to 100 ft from a sensitive well. A "Sensitive water-supply well" is defined as a water-supply well with less than 50 feet of watertight casing where the casing does not penetrate a confining layer or multiple layers of confining materials with an aggregate thickness of 10 feet or more. |
Minnesota | Location | Animal Feedlot, Barnyard, Feeding Or Watering Area |
100 ft from unroofed animal feedlot holding >=300 animal units, 50 ft if feedlot holds more than one animal unit. 50 ft from feeding or watering area. 20 ft if feedlot, confinement area, or kennel holds less than 1 animal unit. Distances are doubled to 200, 100, and 40 ft from a sensitive well. A "Sensitive water-supply well" is defined as a water-supply well with less than 50 feet of watertight casing where the casing does not penetrate a confining layer or multiple layers of confining materials with an aggregate thickness of 10 feet or more. |
Minnesota | Location | Agricultural Chemical Storage Area |
Must be 150 ft. from an area used to prepare or store more than 25 gallons or 100 lbs. dry weight of agricultural chemical. 100 ft if area protected with safeguards as defined in parts 1505.3010 to 1505.3150 for bulk pesticides, or with safeguards as specified in standards of the Department of Agriculture for fertilizers under parts 1510.0370 to 1510.0408 and Minnesota Statutes, chapter 18C. 50 ft if area is protected with safeguards and is covered with watertight roof. |
Minnesota | Licensing | Licensing - General |
License required for construction, repair, and sealing of all wells, installation of pump or pumping equipment. Install, modify, or remove a screen, pitless unit, or pitless adapter. |
Minnesota | Identification | Identification - General |
ID label must be attached to casing in a visible location with stainless steel clamp, band, or strap before well is put into service. Alternatively, the label may be attached to a concrete pump base or pedestal, or at-grade well vault using screws or fasteners. Must be maintained to remain readable. |
Minnesota | Grout | Neat Cement Grout |
A fluid mixture in the proportion of 94 pounds of Portland cement and not more than six gallons of water. Bentonite up to five percent by weight of cement (4.7 pounds of bentonite per 94 pounds of Portland cement) may be used to reduce shrinkage. Not more than 0.6 additional gallons of water may be added for each one percent of bentonite. Admixtures to reduce permeability or control setting time must meet ASTM Standard C494/C494M-04. The minimum density of neat-cement grout using regular (Type 1) Portland cement without bentonite or entrained air is 15.0 pounds per gallon. The minimum density of regular neat-cement grout with bentonite and without entrained air is: |
Minnesota | Grout | Grout - General |
Well must be grouted immediately upon completion of drilling, must be pumped under pressure from bottom to top or base of pitless adapter or unit. If casing depth is <=50ft, must extend from bottom of casing, top of seal or gravel pack, to ground surface or pitless. If casing depth >50ft, annular space below 50 ft must be grouted, except in unconsolidated formations which may be filled with cuttings taken from the borehole and placed without bridging. A layer of bentonite pellets, bentonite chips, or granular bentonite not to exceed five ft in thickness is allowed between a gravel pack and grout, must not extend into a confining layer or extend more than ten ft above the static water level, poured without voids or bridging. |
Minnesota | Grout | Concrete Grout |
Mixture of Portland cement, sand and gravel aggregate, and water so that one cubic yard of concrete contains a minimum of 470 lbs (five 94-lb bags) of Portland cement, a maximum of 30 gallons of water, and sand and gravel aggregate passing a one-inch sieve. Admixtures to reduce permeability or control setting time must meet ASTM Standard C494/C494M-04. Allowed only in wells >=16-inch diameter, <200 ft deep, with <20 ft of water. |
Minnesota | Grout | Bentonite Grout |
Bentonite means an aluminum silicate clay that contains at least 85% montmorillonite and meets API 13A-04. Bentonite Grout is minimum 15% by weight powdered or granular bentonite, no additives to promote temporary viscosity. Add'l 15% by wt. of either washed sand or cuttings taken from borehole may be mixed into bentonite and water slurry. Bentonite must be designed as a grout or well and boring sealant, and must be mixed to manufacturer's specs. To be used in unconsolidated materials. |
Minnesota | Gravel Pack | Gravel Pack - General |
The top of a gravel pack must terminate at least 15 ft below the established ground surface. Must be mineral material or inert, nontoxic artificial materials, contain < 5% calcareous material & be graded, cleaned, & washed. Must not extend more than 10 ft above static water level or 10 ft above or below screen, through a confining layer in violation of 4725.2020, subpart 1a, or through more than 10 ft of open hole. |
Minnesota | Fracturing | Fracturing - General |
Hydrofracturing must be done by a well contractor licensed according to Minnesota Statutes, section 103I.525. |
Minnesota | Location | Surface Water Bodies |
Must be 35 ft horizontally from ordinary high water level of a stream, river, pond, storm water retention pond, or lake, does not apply to area protected by flood control structure accepted by FEMA, a wetland, grassed waterway, depression, culvert, or ditch holding water less than 6 months of the year, or an artificial pond holding less than 5,000 gallons of water. 50 ft from industrial cooling pond, gray water dispersal area. |
Minnesota | Location | Subsurface Disposal Field or Privy |
Must be 50 ft. from subsurface disposal field or privy, except that a sensitive well must be at least 100 ft from subsurface disposal field. A "Sensitive water-supply well" is defined as a water-supply well with less than 50 feet of watertight casing where the casing does not penetrate a confining layer or multiple layers of confining materials with an aggregate thickness of ten feet or more. |
Minnesota | Location | Storm Water Drain Pipe (>=8 In. Diameter) |
Well must be 20 ft. from storm water drain pipe. |
Minnesota | Location | Sewage, Septage, or Sludge |
50 ft from a sewage, septage or sludge land-spreading area. Distance is doubled to 100 ft for a sensitive well. A "Sensitive water-supply well" is defined as a water-supply well with less than 50 feet of watertight casing where the casing does not penetrate a confining layer or multiple layers of confining materials with an aggregate thickness of 10 feet or more. |
Minnesota | Location | Septic Tank, Sewage Lift Station, Sump |
Must be 50 ft. from septic tank, sewage left station, sump. (MN rule, part 4725.4450) |
Minnesota | Location | Septic Tank |
Must be 50 ft. from septic tank. (MN rule 4725.4450) |
Minnesota | Location | Privies |
Must be 50 ft. away for wells > 50 ft. deep; must be 100 ft. away for wells < 50 ft. deep. 20 ft from portable privy or toilet. |
Minnesota | Location | Petroleum |
Must be 150 ft. from an area used to prepare or store more than 25 gallons or 100 lbs. dry weight of petroleum. 100 ft from pipeline used to transport petroleum or crude oil. 50 ft from buried storage tank holding between 56 and 1,100 gallons of petroleum. 20 ft from tank not buried holding between 56 and 1,100 gallons of petroleum. |
Minnesota | Location | Manure Storage Area |
100 ft from solid manure storage area not covered by a roof, safeguarded area used to store agricultural chemicals, or clean or fill ag chemical application equipment protected with safeguards. |
Minnesota | Location | Location - General |
All water wells must be located where there is optimum surface drainage and at highest practical elevation. The well or boring must be accessible for repair and sealing. |
Minnesota | Location | Leaching Pit |
75 ft. Distance is doubled to 150 ft from a sensitive well. A "Sensitive water-supply well" is defined as a water-supply well with less than 50 feet of watertight casing where the casing does not penetrate a confining layer or multiple layers of confining materials with an aggregate thickness of 10 feet or more. |
Minnesota | Location | Landfill, Dump |
300 ft from a landfill or dump containing mixed municipal solid waste from multiple persons, and a permitted demolition debris landfill. |
Minnesota | Location | In-Ground Swimming Pool |
Must be 20 ft. from inground swimming pool. |
Minnesota | Location | Holding Tank |
Must be 50 ft. from a holding tank with anhydrous ammonia, agricultural chemicals, hazardous materials or wastes, each holding < 56 gallons or 100 lbs dry weight. |
Minnesota | Location | Hazardous Substances |
Must be 150 ft. from an area used to prepare or store more than 25 gallons or 100 lbs. dry weight of hazardous substances. 50 ft from storage area for bulk road deicing chemicals, except that a sensitive well must be at least 100 ft from bulk road deicing chemicals. A "Sensitive water-supply well" is defined as a water-supply well with less than 50 feet of watertight casing where the casing does not penetrate a confining layer or multiple layers of confining materials with an aggregate thickness of 10 feet or more. |
Minnesota | Location | Grave, Mausoleum, Animal Burial |
50 ft. |
Minnesota | Location | Frost-Proof Yard Hydrant |
Well must be 10 ft. from frost proof yard hydrant. |
Minnesota | Testing | Testing - General |
All potable water supply wells must be tested for coliform bacteria, nitrate - N. arsenic and must indicate absence of coliform bacteria before use. |
Minnesota | Screens | Screens - General |
Must be connected to casing by threaded, solvent-welded or welded joint, or by a nontoxic packer. Lead packers are prohibited. |
Minnesota | Pressure Tanks | Pressure Tanks - General |
Pressure relief or air release valve must be vented to outside. If buried, must be identified with manufacturer name, serial number, allowable working pressure and year fabricated. Must have interior coating complying with ANSI/NSF Standard 61-2003e if the tank has an interior coating in contact with water; must have minimum 1/4 inch wall thickness for steel pitless adapter tank attached directly to well casing; must have all connection to pressure tank welded or threaded, and must be installed above the water table. |
Minnesota | Pitless Adapters | Pitless Adapters and Units - General |
Required if connection to casing is made less than 12 inches above established ground surface. Must clear I.D. of casing, have all threaded joints watertight with no threads exposed, connect to casing by threaded or welded connection, bolted flange with gasket, clamp and gasket, or compression gasket with materials meeting standards in 4725.2350, 4725.2550, or 4725.6650. Pitless unit using a compression seal must provide for the well casing to extend at least 2.5 inches into the throat of the pitless unit, and compression collar must be held in place with corrosion-resistant bolts, nuts, washers. |
Minnesota | Permitting | Permitting - General |
Notifications are required. |
Minnesota | Packers | Packers - General |
If a screen is attached, screen must be attached to the casing by a threaded, solvent-welded, or welded joint or by a non-toxic packer. Lead packers must not be used. |
Minnesota | Maintenance and Repair | Maintenance & Repair - General |
Materials used in maintenance, replacement, or repair must meet requirements of new installation. |
Minnesota | Location | Watertight Sewage Sump |
Well must be 50 ft. from sewage sump, or 20 ft from watertight sewage sump with a capacity of less than 100 gallons. |
Minnesota | Location | Unused, Unsealed Well Or Boring |
Must be 50 ft. from an unused, unsealed well or boring. |
Missouri | Casing | Plastic |
May be joined by solvent weld, mechanical joints, or threaded joints. Thermoplastic pipe & couplings to meet SDR SCH 40 & SCH 80. To have SDR of 26, 21, 17, or 13.5. To meet ASTM standard F480. Casings must be marked. All joints must be watertight. |
Missouri | Casing | Pipe |
To be new pipe recognized by ASTM A53 grade A or B, A500 grade A or B, or A589. |
Missouri | Casing | Joints |
Recessed or reamed & drifted couplings to be used on threaded casing. To be made by continuous welding, threading, or other approved methods. To be watertight. Tongue & groove type acceptable for concrete. |
Missouri | Casing | Internal Diameter |
To be no < 6 in. unless exempted for a driven well point or jetted well to be equipped w/ 1.25 I.D. |
Missouri | Casing | Drive Shoe |
To equip bottom of driven steel casing. |
Missouri | Casing | Casing - General |
Casing for permanent wells to be of ferrous material, plastic, or concrete material. Casing to terminate no < 2 ft. above max known flood level. Under no conditions shall I.D. casing be <6 inches unless specifically exempted. Shall be watertight, sealed off to formations known to pose health risk. For multi-family wells, must get advanced approval to use plastic casing. |
Missouri | Caps | Caps - General |
Caps for wells w/ Pitless Adapters to be have a screened vent hole pointing downward at least 0.5 in. diameter. Hub cap types not approved. Temporary caps not to allow contamination during installation of pumping equipment. |
Missouri | Additional Requirements | Additional Requirements - General |
Above-grade connections to be threaded, welded, rubber expansion sealer or bolted flanges w/ rubber gaskets. Below-grade connection to be protected by pitless adapter or unit. Connection may also be overlapping well cap. |
Missouri | Abandonment | Abandonment - General |
Bentonite or cement grout to be used. All abandoned wells to be plugged through approved methods described in 10 CSR 23-3.110 Plugging of Wells. Contact The Division if there is a question of proper procedure. A permitted well or pump installation contractor must be used to plug the well. A report of the method of plugging shall be filed with the division on a registration report form that is provided by the division. |
Minnesota | Vents | Vents - General |
All wells must be vented except flowing wells. Vent must terminate minimum 12 inches above ground surface, have water tight joints and terminate at least 5 ft above regional flood level unless provided with watertight seal as specified in part 4725.4350 subpart 2. Must be screened with noncorrosive mech screen having openings of 1/16 inch or less and pointed downward and be connected to the casing according to part 4725.4850. Any toxic or flammable gas must be vented from the well to the outside atmosphere. |
Missouri | Grout | Bentonite Slurry |
Must have solids content of at least 20%. Additives to affect viscosity and set-up time are acceptable but must not be a potential contaminant. |
Missouri | Grout | Bentonite |
Bentonite to be applied slower than manufacturer\'s specifications. Chipped or pelletized bentonite not to be used in annular space < 1 in. May be hydrated. Only bentonite designed to prevent flash hydration & to fall through standing water to be used. |
Missouri | Electrical Connection | Electrical Connection - General |
Electric wire not to be run through pitless adapter. To be performed well installation contractor or pump installation contractor. To conform to existing electric codes. |
Missouri | Drop Pipe | Drop Pipe - General |
If metallic drop pipe is used, thickness to be at least SCH 40. Must be thermoplastic ABC or PVC that have SCH 80 or thicker walls. |
Missouri | Disinfection | Disinfection - General |
Disinfect wells w/ 100 ppm chlorine solution. Min contact tremie of 2 hours before pumping well to waste & flushing chlorine soln. When repairing wells, disinfection to be accomplished w/ a 200 ppm chlorine solution. Caution: The chlorinated water must not leave the owner’s property. If it does, the owner must report to the Water Pollution Control Program, Division of Environmental Quality. |
Missouri | Development | Development - General |
Develop to remove drill cuttings, drilling fluid, & finer fraction of gravel pack. |
Missouri | Cross Connection | Cross Connection - General |
Prohibited unless suitable protective device like break tank or backflow preventor is installed & maintained. |
Missouri | Casing | Vertical Extension |
To extend at least 1 ft. above finished surface grade. Shall terminate at least 2 ft above maximum known floodwater elevation. |
Missouri | Casing | Steel |
To be new & at least 6 in. nominal size, 13 lb./ft, & 0.188 wall thickness. |
Missouri | Location | Landfill, Lagoon, Petroleum Lines |
300 ft. |
Missouri | Location | Earthen Concrete, Manure Storage |
300 ft. |
Missouri | Location | Chemical Storage Area |
300 ft. |
Missouri | Location | Cesspools |
100 ft, if well casing is <80 ft in depth and does not encounter at least 10 ft impervious material must be 150 ft. |
Missouri | Location | Buried Sewer, Septic Tank |
50 ft, if well casing is <80 ft in depth and does not encounter at least 10 ft impervious material must be 150 ft. |