State Well Codes

The State Well Codes database stores state standards for the construction of private water wells.

Included in the database is state-specific information on various codes related to well construction and siting. To find information on your state or other states, use the searchable database below.

Please note that this database is intended as a guide and occasionally standards change. WSC updates the database periodically, but we encourage you to obtain a full list of state well codes from your state environmental agency or contact the wellcare® Hotline for assistance. 

If you have questions about the database, corrections or updates, please contact Charlene Bean.

Please click on the State Name in the list below for well code information. If you would like to alphabetize the table, click on the column name in blue.

Displaying 1301 - 1400 of 2328 1 12 13 14 15 16 24
State Category Subcategory Standard Description
Kansas Cross Connection Cross Connection - General

Avoid contamination. Water from two or more separate aquifers shall be separated by sealing the annulus between the aquifers with grout.

Kansas Casing Casing - General

New PVC, wrought iron, steel or other KDHE approved materials. Watertight, and will extend at least 12 in. above surface, and no less than 20 ft. below ground level. Shall be an above-grade surface completion, at-grade surface completion may be used if all requirements of subsection (s) are met. Casing may be cut off below the ground surface to install a pitless well adapter or unit. No opening shall be made through casing except for pitless well adapter or unit installation.

Kansas Caps Caps - General

Sanitary seal required

Kansas Additional Requirements Additional Requirements - General

Natural organic or nutrient producing material not to be used during construction. Toxic material shall not be used in the construction, reconstruction, treatment, or plugging of a water well, unless the material is flushed from the water well before use. Wells not to be constructed in pits, basements, garages, or crawl spaces. Known contaminated water-producing zones in aquifer shall be cased and grouted to prevent movement of groundwater from that zone into fresh groundwater zones.

Kentucky Fracturing Fracturing - General

No Standard Specified.

Kentucky Electrical Connection Electrical Connection - General

No Standard Specified.

Kentucky Disinfection Disinfection - General

Chlorine to be at least 100 ppm to water, use chlorine bleach or hypochlorite granules. Circulate solution for 30 minutes, let stand for 30 minutes. Purge well of all chlorinated water.

Kentucky Discharge Pipe Discharge Pipe - General

No Standard Specified.

Kentucky Development Development - General

Shall be developed until the column of water in the well is free of visible sediment.

Kentucky Construction Construction - General

Annular space shall be filled with neat cement-bentonite slurry, bentonite, native clay, or drill cuttings. Casing to be set into bedrock a min of 10 ft. if in consolidated formations when overburden is < 30 ft. thick. Casing to be set into bedrock a min of 2 ft. if in consolidated formations when overburden is > 30 ft. thick. Casing to extend a min of 2 ft. into stable rock below the lowermost void whenever voids are encountered. Coupling to be cemented to bottom of casing. Diameter of drill hole to be min of 1 3/4 in. > I.D. of casing. Drill hole diameter to be a min of 1 3/4 in. > casing diameter. Drill hole to be a min of 2 in. > I.D. of casing. Drilled Wells in Consolidated Formations: Drilled Wells in Unconsolidated Formations: If obtaining water from a lower formation, casing to extend at least 2 ft. below crevices or fractures. If overburden is 30 ft. thick or less, watertight seal to reach depth of at least 20 ft. & 10 ft. into bedrock. If overburden is > 30 ft. thick, watertight seal to be a min of 2 ft. into stable rock. If pumping level is < 20 ft. below ground surface, casing to extend 10 ft. below pumping level. If pumping level is > 20 ft. below ground surface, casing to extend 5 ft. below pumping level. If temporary surface casing is to be installed, annular space to be filled to depth of at least 20 ft. Joints to be solvent-cemented or threaded & coupled. Plastic Casing Installations: Space may also be filled with a mechanical packer. Treat pipe spigot & socket w/ cleaner-primer. Well casing to be driven when water is obtained from thick, unstable bedrock or overburden. All materials used in construction, modification and abandonment shall be approved for use in water wells by NSF, ASTM or API standards. Materials containing lead shall not be used in the construction of a water supply well. shall be constructed to allow access for repairs, maintenance, treatment, and inspection.

Kentucky Casing Joints

Joints and couplings shall be welded or threaded, and watertight.

Kentucky Casing Casing - General

Extend to at least 20 ft. below surface. Casing not to be cut off or into below ground unless a pitless well unit or adapter is being installed. Materials must meet NSF, ASTM or API standards. Outer casing to be removed after well completion.

Kentucky Caps Caps - General

To accompany well upon completion, must be watertight.

Kentucky Bases Bases - General

No Standard Specified.

Kentucky Access Ports & Tubes Access Ports & Tubes - General

No Standard Specified.

Kentucky Abandonment Abandonment - General

At least the upper 5 ft. of casing, liner pipe, brick, stone, & metal to be removed. Driller shall fill the well with sealing materials or inert earth materials from bottom of the well to a minimum of 20 ft below ground surface, and fill remainder with sealing materials to minimum of 5 ft below ground surface. Uppermost 5 ft of well shall be filled with sealing materials or other suitable, inert earth material. Driven Wells: remove casing and screens, introduce sealing materials simultaneously from bottom of well to maximum 5 ft below finished ground surface Use sealing materials, clay, or other inert materials suitable to proposed land use to fill upper 5 ft. Flowing Artesian Wells: Plug with neat cement grout that is pumped under pressure and mixed with minimum quantity of water that will permit handling. Place well packer, cast-iron plug, or temporary bridge at bottom of confining formation immediately overlying artesian water-bearing horizon to seal off flow. Reporting required within 60 days following abandonment.

Kansas Well Pits or Vaults Well Pits Or Vaults - General

Not permitted.

Kansas Vents Vents - General

Vent must be used and shall terminate at least 1 ft. above ground surface. Vent shall be screened with brass, bronze, copper screen, or other screen materials approved by the secretary that are 16-mesh or greater, and turned down in a full 180-degree return bend to prevent entrance of contaminating materials.

Kansas Testing Testing - General

28-30-10

Kansas Seals Seals - General

Sanitary seals required and must be watertight.

Kentucky Location Property Lines

10 ft. Includes utility lines or roadway right of way.

Kentucky Location Manure Piles

75 ft.

Kentucky Location Location - General

Minimum distances should be doubled if unconsolidated material is less than 20 ft thick and composed of predominantly sand or gravel. Avoid flood zones unless no alternative site available. Casing to terminate no less than 2 ft. above maximum flood level. Wells not to be constructed in pits or basements.

Kentucky Location Leaching Pit

100 ft.

Kentucky Location Lateral Fields

70 ft.

Kentucky Location Cemeteries

75 ft.

Kentucky Location Building Projections

5 ft.

Kentucky Location Barnyard

50 ft.

Kentucky Licensing Licensing - General

Driller must be certified.

Kentucky Identification Identification - General

No Standard Specified.

Kentucky Well Pits or Vaults Well Pits Or Vaults - General

New shall not be constructed and existing pits shall not be modified. Certified driller modifying a well shall eliminate existing well pit and shall extend the casing a minimum of 4 inches above finished ground surface.

Kentucky Well Head Completion Well Head Completion - General

Casing or riser pipe to terminate no less than 4 in. above finished ground surface and slope the ground surface away from the well. Casing shall terminate minimum 2 ft above maximum known flood elevation.

Kentucky Vents Vents - General

A vent shall consist of a pipe extending above the top of the well and above known flood elevations, with the open end turned down, and the open end shall be covered with 24 mesh or finer screen of durable material. For wells with naturally occurring methane, a vent shall be installed.

Kentucky Testing Testing - General

Water to be tested for fecal coliform within 30 days of completion, disinfection, or modification of the well. Sample collected after residual chlorine purged. Samples shall not be frozen, and kept at 40 degrees F, containers sterile glass or plastic, and testing conducted at a laboratory certified in accordance with 401 KAR 8:040.

Kentucky Seals Seals - General

To accompany well upon completion.

Kentucky Screens Screens - General

Capable of withstanding stress pipe is subjected to and corrosiveness of water. Steel or PVC screens with minimum inside diameter of 4 in. shall be installed, except for bored, drive or jetted wells. Shall be centered in borehole. Steel screen joints and couplings shall be welded or threaded. PVC screens shall have minimum SDR 26, Must have minimum Impact Classification of IC-1, ASTM D1784-07 or F480-066. ASTM F480-06b, SDR, SCH40 and SCH 80. Must meet or exceed NSF 14. Joints and couplings shall be welded, cemented, or threaded. Screen slot size shall prevent entry of sediment or other harmful material.

Kentucky Pumps Pumps - General

No Standard Specified.

Kentucky Pump Pits Pump Pits - General

No Standard Specified.

Kentucky Plumbness & Alignment Plumbness & Alignment - General

Make certain that bore hole can receive casing w/o binding & that casing will not interfere w/ pump installation.

Kentucky Plumbing Connection Plumbing Connection - General

No Standard Specified.

Kentucky Pitless Adapters Pitless Adapters - General

Must have leak-proof seal. If a frost-free hydrant is installed, a Dual Check Valve Backflow Preventer that meets the specifications of ASSE 1024 Performance Requirements for Dual Check Backflow Preventers shall be installed between the pitless adapter and the frost-free hydrant.

Kentucky Permitting Permitting - General

No Standard Specified.

Kentucky Meters Meters - General

No Standard Specified.

Kentucky Maintenance & Repair Maintenance & Repair - General

Existing well pits not to be modified.

Kentucky Location Subsurface Seepage Tile

75 ft.

Kentucky Location Septic Tank or Sewer Line

50 ft.

Lousiana Grout Cement-Bentonite

May have additives. To consist of 8% or less bentonite by dry weight of cement & at least 10 gal. of water per sack of cement.

Lousiana Gravel/Sand-Packed Wells Gravel/Sand-Packed Wells - General

No Standard Specified.

Lousiana Gravel Pack Gravel Pack - General

Gravel to be of well-rounded siliceous material. Limestone & shale not to be used. May be used if interval to be screened consists of fine uniform sand or medium & coarse sand. Uniformity coefficient to be 2.5 or less.

Lousiana Explosives Explosives - General

Prohibited.

Lousiana Electrical Connection Electrical Connection - General

No Standard Specified.

Lousiana Disinfection Disinfection - General

Disinfect wells prior to use. Negative bacteriological analysis required.

Lousiana Discharge Pipe Discharge Pipe - General

No Standard Specified.

Lousiana Development Development - General

Chemical mixture to stand in well for at least 1 hr. Chemicals to meet AWWA or EPA standards. Development of gravel-packed wells, to be accomplished by jetting or cross washing method. Glassy polyphosphate chemicals are beneficial to development. Observed specific capacity to = theoretical specific capacity. Sand not to exceed 5 mg/L of water. To be backwashed or surged by starting & stopping pump. To be jetted w/ water (crosswashing). Use chemicals designed for developing & redeveloping. Wells to be developed at yield of 1.5x proposed pumping rate. Wells to be developed by surging w/ a plunger of piston while jetting using an air-lift. Wells to be over-pumped. Wells to be relatively sand free & have less encrustation problems.

Lousiana Casing Structural Steel

To meet ASTM A36, ASTM A242, ASTM 570-79, ASTM A283, or ASTM A441.

Lousiana Casing Standard & Line Steel Pipe

To meet API 5A, API 5L, API 5LX, ASTM A53, ASTM A120, ASTM A134, ASTM A135, or ASTM A139. To meet ASTM A211, AWWA C201, AWWA C202, or Underwriters Laboratories Standard 888.

Lousiana Casing Solvent Cement

To conform to ASTM D-2564.

Lousiana Casing Plastic

To be designated as PVC 1120 or PVC 1220 & have an ultra-violet degradation inhibitor. To be new PVC in accordance w/ AWWA A-100, ASTM F-480, or ASTM D-2241.

Lousiana Casing Joints

Shall be threaded, integral bell pipe, or one piece couplings. Solvent-weld tapered bell & spigot joints to meet ASTM D-2672.

Lousiana Casing High Strength Carbon Steel

No standard specification.

Lousiana Casing Casing - General

If threaded joints are used, thickness to be at least SCH 80. Joining techniques to follow manufacturer\'s recommendations or ASTM D2855. Not to be driven, pushed, or forced into formation. PVC casing not to support the pump/motor. To be at least SCH 40 or 80. To have a SDR of 26, 21, or 17. To project at least 1 ft. above ground level, pump house floor, or top of concrete slab.

Lousiana Caps Caps - General

No Standard Specified.

Lousiana Blasting Blasting - General

Prohibited.

Lousiana Additional Requirements Additional Requirements - General

Concrete slabs to be at least 4 in. thick & extending at least 2.5 ft. from well in every direction. Sample tap to be on the well discharge line & be of a smooth nozzle type turned downward. Slabs to be sloped & drain away from well.

Lousiana Access Ports & Tubes Access Ports & Tubes - General

No Standard Specified.

Lousiana Abandonment Abandonment - General

Cement-bentonite slurry is the preferred material for plugging. If permitted, heavy drilling mud or bentonite slurry weighing no less than 9 lb./gal. may be used to fill or plug. It is preferable for plugging to be applied using the pump-down method, in one continuos operation. Neat cement may also be used. Obstructions in well to be removed prior to plugging. Plugging & filler material to be free of foreign & organic additives. Pouring or dropping the material through water is not permitted. Top of casing to be cut off a min of 3 ft. below surface in areas subject to subsidence and/or farming.

Lousiana Pitless Adapters Pitless Adapters - General

No Standard Specified.

Lousiana Permitting Permitting - General

No Standard Specified.

Lousiana Meters Meters - General

No Standard Specified.

Lousiana Maintenance & Repair Maintenance & Repair - General

If sanitary seal is removed, drop pipe, jet line, & pump/motor to be cleaned.

Lousiana Location Water Well

25 ft.

Lousiana Location Subsurface Absorption Fields, Pits

100 ft.

Lousiana Location Storm Or Sanitary Sewer

50 ft.

Lousiana Location Solid-Waste Dumps

100 ft.

Lousiana Location Sewer Of SCH 40 Plastic Pipe

30 ft.

Lousiana Location Sewer Of Cast Iron W/ Leaded Joints

30 ft.

Lousiana Location Septic Tank

50 ft.

Lousiana Location Sanitary Landfills, Feed Lots, Manure

100 ft.

Lousiana Location Outdoor Privies, Oxidation Ponds

100 ft.

Lousiana Location Location - General

Casing to be at least 2 ft. above maximum flood level. Locate wells to avoid flooding. Wells not to be constructed within 200 ft. of the levees. Wells not to be located in pits, basements, or the foundation of a building.

Lousiana Location Drainage Canal, Ditch, Stream

50 ft.

Lousiana Location Cesspools

100 ft.

Lousiana Licensing Licensing - General

Individuals must pass an exam. Wells & holes to be constructed by a licensed contractor (driller).

Lousiana Identification Identification - General

Casing pipe & couplings shall be marked according to ASTM F-480.

Lousiana Grout Neat Cement

May be used where mixture is 5 gal. of water per sack of cement.

Lousiana Grout Grout - General

Allow space for tremie pipe. Community public wells to be cemented their full depth from top of the producing aquifer to ground surface. Conductor pipe to be cemented into place & annular space to be grouted w/ cement-bentonite slurry. Domestic wells to be cemented from a min depth of 10 ft. to ground surface using pump-down or gravity method. If sands between ground surface & production sand contain poor water, grout to extend to at least 20 ft. below. Non-community public wells to be cemented from a min depth of 50 ft. to surface. Pump-down method may be the Halliburton, inner string cementing, or positive placement-exterior method. Retainer, packer, shale trap, boot, or plug to attach to casing. Shall be placed by circulation or pump-down method. Slurry to be placed in annular space from bottom to top in one continuous operation. Slurry to fill a min annular space of 1.5 in. for 4 in. wells or less, & fill a min of 2 in. for 6 in. wells or greater. To be a cement-bentonite slurry.

Massachusetts Casing Steel

To be coupled using threaded casing, coupling, or welded joints. To be SCH 40 that complies w/ AWWA. In all cases, the wall thickness should be sufficient to withstand hydraulic loading if the casing is pumped dry and should have a collapse strength greater than one pound per square inch for every 2.31 feet of depth beneath the top of the aquifer. To be used w/ cable tool drilling. Welding joints to conform to AWWA C206. Each length shall be legibly marked in accordance with ASTM, API or AWWA standards.

Massachusetts Casing Driveshoe

To be used when casing is installed.

Massachusetts Casing Casing - General

Casing to extend at least 12 in. above finished ground surface. Casing to extend at least 2 ft. above level of highest recorded flood when well is constructed in a floodplain. To be steel or thermoplastic.

Massachusetts Caps Caps - General

Any well, except a dug well, that does not terminate in the base of a pump should be equipped with a sanitary seal or watertight well cap designed to prevent surface water and foreign matter from entering the well. A flowing artesian well should be equipped with a shut-off valve and a backflow preventer so that the flow of water can be stopped completely when the well is not in use.. Temporary covered should be installed during interruptions of 1 week or longer. Semi-permanent watertight cover should be installed. For steel-cased well, semi-perm covered of steel or cast iron cap of at least 3/16 inches thick should be tack welded to top of casing.

Massachusetts Access Ports & Tubes Access Ports & Tubes - General

All new wells (except dug wells) and wells repaired or altered shall be equipped with access port or pressure gage fitting to include a control valve. Access ports should have inside diameter of at least 1/2 inch and fitted with threaded plug or cap. Airlines and removable well caps are acceptable as access ports. When a spool type of pitless adapter is used which prevents the casing from having an unobstructed opening to the water surface, a 3/4 inch diameter pipe may be attached to the spool and extended to the surface below the well cap.

Massachusetts Abandonment Abandonment - General

Casing to be cut off before seal is placed. Materials not to be poured. Materials to be introduced into bottom of well & proceed up to about 4 ft. below ground surface. Slab to be at least 6 in. thick & at least 2 ft. > diameter of well casing or borehole wall. Surface seal to be emplaced no sooner than 24 hours after well has been plugged. To be performed only by registered well drillers. Top 4 ft. of well to be filled w/ concrete. Top of seal to comprise a concrete slab above top of plugged well. Wells to be plugged w/ neat cement grout, sand cement grout, concrete, or bentonite grout. To temporarily abandon, top of casing should be sealed with watertight threaded cap or steel plate welded watertight to top of casing. If pump or well seal is watertight, the pump may be left in place. A well that has, after extended use, been temporarily abandoned for 3 years should be permanently abandoned.

Lousiana Well Pits or Vaults Well Pits Or Vaults - General

No Standard Specified.

Lousiana Well Head Completion Well Head Completion - General

No Standard Specified.

Lousiana Vents Vents - General

Openings to be turned downward & screened. Required for public supply water wells & recommended for others. To be no less than 0.5 in. in diameter. To be no less than 1 ft. above top of well casing. To be piped water-tight & to a point at least 2 ft. above highest flood level within a 10 year period. To prevent entrance of contaminants.

Lousiana Testing Testing - General

Determine yield.

Lousiana Seals Seals - General

To be installed at top of casing for all wells. To be of cast iron, steel, aluminum, high impact plastic, neoprene, or a combination of these.

Lousiana Screens Screens - General

Shall be on every water well. Type to be determined by cost, water quality, well yield, required strength, & contractor\'s experience.

Lousiana Pumps Bases

Casing to project at least 1 in. above foundation level. To accompany all surface-mounted pumps/motors. To be of split per or solid pedestal type.

Lousiana Pump Pits Pump Pits - General

No Standard Specified.

Displaying 1301 - 1400 of 2328 1 12 13 14 15 16 24
Right Menu Icon