New-State Well Codes

The State Well Codes database stores state standards for the construction of private water wells.

Included in the database is state-specific information on various codes related to well construction and siting. To find information on your state or other states, use the searchable database below.

Please note that this database is intended as a guide and occasionally standards change. WSC updates the database periodically, but we encourage you to obtain a full list of state well codes from your state environmental agency or contact the wellcare® Hotline for assistance. 

If you have questions about the database, corrections or updates, please contact Charlene Bean.

Please click on the State Name in the list below for well code information. If you would like to alphabetize the table, click on the column name in blue.

Displaying 2301 - 2328 of 2328 1 22 23 24
State Category Subcategory Standard Description
Wisconsin Cross Connection Cross Connection - General

When a well is installed with a submersible pump and an above ground discharge, it shall contain an UL approved check valve and an air-vacuum relief valve prior to any buried portion of the discharge pipe. When water is pumped to a pond or other body of water, the end of the pump discharge pipe shall be terminated at least 2 feet above the highest elevation of the water in the pond or other body of water.

Illinois Location Buildings

When a well must be located adjacent to a building, it shall be located so that the center line of the well extended vertically will clear any projection from the building by not less than 2 ft.

North Dakota Location Building Projections

When a well must be located adjacent to a building, it shall be located so that the centerline of the well extended vertically will clear any projection from the building by not less than 2 ft.

Washington Seals Artesian Wells

When flowing conditions, operator will have a written sealing plan prepared prior to construction. Plan shal identify sealing material and method to be used, at least one alternative sealing method, and emergency contingency section to identify steps taken if flow cannot be controlled. To be sealed into confining stratum, and equiped with a control valve if flowing at surface. To be completed w/seals, packers or grout that eliminates leakage around the casing.

Vermont Location Location - Variances

When meeting the minimum isolation distances is physically unworkable, or location of the subsurface disposal field can not be determined, additional protective measures must be used. Additional protection shall be provided through the use of additional casing and grouting of any annular space. Driller shall discuss the well location problems with the owner and the final location and use of additional protective measures shall be agreed to before construction. Where possible, the well should be located in a non-hazardous location where the well will not be subject to damage from vehicles and similar hazards.

Colorado Vents Vents - General

When needed - must terminate a minimum of 1 ft above the finished ground level, be turned down, and screened. Must be constructed to vent all gases to the atmosphere outside of a building, be connected with watertight joints and permit air to freely enter and exit.

Connecticut Well Pits or Vaults Drain

When no danger of flood or back flow, drain onto ground surface using graded pipe of not less than 1/8 in/ft toward outlet. Junction of pit floor and drain pipe, drain pipe and joints to be watertight. Any drain to ground surface shall be screened prevent entrance of animals and insects. Connections with sewer, house drain or storm drain are prohibited.

Wisconsin Grout Grout - General

When rotary drilling mud and cuttings or clay slurry are used to seal the annular space of a well as specified by Tables I and II, a mud balance shall be used to determine that the mud weight is at least 11 pounds per gallon.

Oregon Grout Cement

When used for sealing material, must meet following requirements: 1) composed of uniformly mixed slurry of Portland cement or High Early Strength Type III Portland cement and potable water, or High-alumina cement and potable water, mixed in following proportions (Type of Cement — Gallons of Water Per Sack of Dry Cement, respectively): (a) Portland Cement — 4-1/2 to 6; (b) High Early Strength Type III Portland Cement — 5-1/2 to 6-1/2; (c) High-alumina Cement — 4-1/2 to 6. Additives to increase fluidity, reduce shrinkage or control time of set may be used, expanding agents such as aluminum powder may be used at a rate not exceeding 0.075 oz/sack of dry cement. Calcium chloride should not exceed 2 lb/sack dry cement. High-alumina cement and Portland cement of any type shall not be mixed. Other types of cement not to be used w/o approval. In no case shall sand or aggregate be added to cement grout mixtures. In no case shall permanent well casing be moved or driven following placement and initial set of cement grout.

Idaho Screens Screens - General

When used, must be commercially manufactured, be slotted, louvered or wire wrapped, and be installed according the manufacturer's specifications.

Illinois Pumps Pumps - General

Where a chemical injection system is directly connected to a water well used for irrigation, a backflow device shall be installed in accordance with Section 925.40 of the Illinois Water Well Pump Installation Code. Installation shall be made only by or under supervision of persons, firms or corporations holding a valid license under the Illinois Water Well and Pump Installation Contractor's License Code [415 ILCS 35] unless exempt from the provisions of that Act.

Vermont Grout Clay Seal/Bentonite

Where annular opening is > 6 inches, clay seal of clean local clay mixed with at least 10% swelling benontite may be used when approved by the Secretary.

Virginia Casing Class III A Wells

Where annular space is grouted to min depth of 20 ft., well to be cased at least 100 ft. Casings shall be steel, stainless steel or plastic.

Virginia Casing Class III B Wells

Where annular space is grouted to min depth of 50 ft., well to be cased at least 50 ft. Casings shall be steel, stainless steel or plastic.

Illinois Seals Seals - General

Where existing wells have buried well seals, the seal shall be replaced with a pitless well adapter, or the casing shall be extended above the ground surface in accordance with Section 920.90(c) of the Illinois Water Well Construction Code (77 Ill. Adm. Code 920) when the existing well seal is removed.

Michigan Screens Screens - General

Where installed on a casing that is less than 4 inches inside diameter, shall be telescoped and removable.

Michigan Location Location - General

Where possible, shall be located upgradient and maximum practical distance from potential or known source of contamination. Shall be accessible for cleaning, treatment, repair, testing, and inspection. Shall not be located in area subject to flooding unless protected as prescribed in writing by health officer.

Vermont Electrical Connection Electrical Connection - General

Wiring in well to be done under license of licensed electrician. Wiring outside of casing to be contained in suitable conduit or pipe from cap at least 2 ft. below surface.

Oregon Construction Filter Pack Wells

With Surface Casing - watertight, welded, steel plate at least 3/16 inch in thickness to be installed between the inner production casing and the outer surface casing at the wellhead. A watertight fill port with threaded cap may be installed for the purpose of placing additional filter pack material in the well. W/O Surface Casing - if permanent casing not installed, filler tubes are to be used, oversize well bore having nominal diameter of ≥4 inches than nominal diameter of permanent casing. A suitable plug to be installed between filter pack and grout seal. Watertight fill pipe with threaded cap may be installed for purpose of placing add'l filter pack material. O.D. of fill pipe shall not exceed 1/2 thickness of grout seal surrounding permanent well casing and to be centered in annular space.

Texas Check Valves Check Valve - General

With the exception of jet pumps, a check valve or an air gap shall be installed in a water line between the well casing and the pressure tank.

New York Location Intermittent Sand Filter

Without watertight liner, 100 ft.

West Virginia Abandonment Abandonment - General

Work must be performed by WV certified water well driller. All wells to be completely filled w/bentonite or cement grout. Wells in unconsolidated formations to be sealed w/bentonite or bentonite-cement mix from top to bottom. If well penetrates limestone or other creviced formation, stone, pea gravel, or other bridging agents may be used. Hand dug or bucket wells exceeding 24 inches in diameter to be abandoned using same method as wells in unconsolidated material. Screens, casings, liner pipes, pumps, wiring, valves, to be pulled when possible.

Utah Licensing Licensing - General

Work to be completed by licensed well driller, installation and repair of pumps must be completed by a licensed well driller or licensed pump installer.

West Virginia Caps Caps - General

WSC approved vector proof cap and shall provide for ventilation.

North Dakota Testing Testing - General

Yield and drawdown test: should include static water level, pumping rate, drawdown measurements, recovery water levels, and depth of pump setting. Contractor should advise well owner that one or more samples should be submitted for bacteriological analysis and should not be used until satisfactory results are obtained. Every new, modified, or reconditioned ground water source should be examined for its chemical characteristics by tests of a representative sample in a department or other approved laboratory. The samples should be collected and tested as soon as practical.

Colorado Testing Testing - General

Yield estimate or yield test to determine a stabilized yield for the well and production equipment test to determine the production capacity of the equipment.

Maryland Testing Testing - General

Yield test required for domestic water supply wells. Shall produce minimum of 1 gpm for 6 hrs. Replacement wells servicing existing dwelling exempt from gpm requirement. Water yield test may be required by Approving Authority in Hydro Areas 1,2,4&5, each well in Hydro Area 3 shall have yield test in accordance with regulation, except where County Water and Sewer Plan delineate that mandatory yield test be waived. Yield test procedures provided §G(1) of this regulation.

Alabama Testing Testing - General

Yield test to be performed & reported.