wellcare® Hotline: 888-395-1033
The State Well Codes database stores state standards for the construction of private water wells.
Included in the database is state-specific information on various codes related to well construction and siting. To find information on your state or other states, use the searchable database below.
Please note that this database is intended as a guide and occasionally standards change. WSC updates the database periodically, but we encourage you to obtain a full list of state well codes from your state environmental agency or contact the wellcare® Hotline for assistance.
If you have questions about the database, corrections or updates, please contact Charlene Bean.
Please click on the State Name in the list below for well code information. If you would like to alphabetize the table, click on the column name in blue.
| State | Category | Subcategory | Standard Description |
|---|---|---|---|
| Alabama | Casing | Nonporous Concrete Pipe |
50% cement, 50% aggregate. To be grouted to 20 ft. The upper 20 feet of the |
| Alabama | Casing | Diameter |
minimum outside diameter of 4.5 inches. |
| Alabama | Casing | Casing - General |
Casing may be driven, lowered, or installed in any manner which will affect a continuous watertight installation. In those wells where there is an annulus, it shall be filled with puddled clay and/or cement grout in the manner prescribed in Rule .06 (a) (1). |
| Alabama | Caps | Caps - General |
all wells shall be left with a secure cap which will not permit the well to become contaminated during construction. |
| Alabama | Blasting | Blasting - General |
Notify Department 14 days prior to reconditioning any well by blasting. |
| Alabama | Abandonment | Abandonment - General |
Top 20 ft. to be filled with cement grout or concrete. Wells to be filled with puddled clay having 50 ppm chlorine within 20 ft. of top. |
| Alabama | Abandonment | Abandonment - General |
Abandoned wells & boreholes to be filled to prevent contamination. Fill with neat cement or in accordance with AWWA Standards. Top 20 ft. must be sealed with neat cement and no material that could impart taste, odor, or toxic components to water may be used in the sealing process. |
| Alabama | Location | Primary Electrical Services |
At least 75 ft. away |
| Alabama | Location | Location - General |
All wells should be above 100 yr. flood plain. |
| Alabama | Location | Field Lines |
100 ft. |
| Alabama | Location | Cess Pool |
At least 150 ft. away |
| Alabama | Location | Barnyard |
At least 150 ft. away |
| Alabama | Licensing | Licensing - General |
Must have at least 2 years of experience under a licensed well driller and make a minimum score of 70 percent on a Board authorized examination prior to being licensed. |
| Alabama | Grout | Grout - General |
Ratio of one sack of Portland cement to 6 gal water. |
| Alabama | Grout | Grout - General |
Flow in continuous operation until annular space is filled & overflowing. In wells > 100 ft., grout to be no < 100 ft. from surface to end of grout zone. Minimum annular space to be 3 in. Non-community wells to be grouted as above or by tremie pipe. Pressure cement grout. To be added at the bottom of outer casing & under pressure. see regulation 335-7-5-.13 |
| Alabama | Disinfection | Disinfection - General |
Wells should be subjected to 50 ppm chlorine solution for at least 12 hrs. |
| Alabama | Disinfection | Disinfection - General |
1. Contamination may occur. 2. Total coliform of raw water > 20 per 100 mL but is < 100 per 100 mL for 4 consecutive months. 3. Avg. fecal coliform count of raw water > 5 per 100 mL but is < 20 per 100 mL for 4 months. Chlorine concentration time of at least 60 to be used when turbidity is < 5 NTU and: Residual for chlorine to be no < 0.2 mg/L free chlorine. Should a disinfectant other than chlorine be used, an equivalent CT time will be provided by the Department. |
| Alabama | Development | Development - General |
Well will be developed to its max practical yield. |
| Alabama | Development | Development - General |
Wells shall be thoroughly developed to remove all sand, cuttings and drilling fluids from the well and aquifer. The permanent pumping equipment may not be used to develop a well. |
| Alabama | Construction | Construction - General |
Air rotary equip. should have pump delivering 3 gpm of water. Casing shall be no less than 20 feet. Casing size in mud rotary wells will be at least 4 1/2 O.D. Casing will be sealed. Casing will extend 1 ft. above ground. Fifty ft. of annulus will be sealed and 20 ft. grouted if impervious layer is not encountered. Holes to be properly backfilled. Wells with casing >8 in. in I.D. will be grouted to > or = to 20 ft. |
| Alabama | Construction | Construction - General |
Drill cuttings to be obtained at 10 foot intervals & all pronounced changes in formations. Submit cuttings to geologist. See Statutory Authority: Code of Alabama 1975, 22-24-8 |
| Alabama | Casing | Steel |
Must be welded or threaded & coupled. Schedule 30. Must be approved for potable water by NSF. |
| Alabama | Vents | Vents - General |
No Standard Specified. |
| Alabama | Testing | Testing - General |
Yield test to be performed & reported. |
| Alabama | Screens | Screens - General |
Requires approval of NSF. See Alabama Department of Environmental Management Regulations, Chapter 335-9-1-.05 |
| Alabama | Pumps | Pumps - General |
See Alabama Department of Environmental Management, Regulation - Chapter 335-7-5 |
| Alabama | Pitless Adapters | Pitless Adapters - General |
No Standard Specified. |
| Alabama | Permitting | Permitting - General |
Must file Notification of Intent to Drill form before drilling, and a Certification of Completion form within 30 days of completion. |
| Alabama | Packers | Packers - General |
No Standard Specified. |
| Alabama | Location | Septic Tank |
At least 100 ft. away |
| Alabama | Location | Secondary Electrical Services |
At least 10 ft. away |
| Alabama | Location | Roofs |
At least 2 ft. away |
| Alaska | Licensing | Licensing - General |
Must have a general or subcontractor's license. |
| Alaska | Grout | Grout - General |
At least 10 ft. of continuous grouting within first 20 ft below ground surface or alternate method approved by the Dept. Watertight cement grout, sealing clay, bentonite or equivalent material approved by the Dept. |
| Alaska | Disinfection | Disinfection - General |
Must be flushed of sediment prior to construction following ANSI/AWWA Standard A 100-97. |
| Alaska | Development | Development - General |
No Standard Specified. |
| Alaska | Construction | Construction - General |
Driller shall file a report within 45 days after completion with the Dept and property owner. |
| Alaska | Cleaning | Cleaning - General |
No Standard Specified. |
| Alaska | Casing | Casing - General |
Must have a sanitary seal. Shall terminate at least 1 ft. above ground level or well house floor. |
| Alaska | Caps | Caps - General |
No Standard Specified. |
| Alaska | Blasting | Blasting - General |
No Standard Specified. |
| Alaska | Additional Requirements | Additional Requirements - General |
At least 10 ft. in all directions from well, surface must be sloped to drain away from well. Driller's log, maps, and photos must be submitted to Dept. No cross-connection with sewer system. Well must be protected against flooding. Well pits are prohibited unless they are exempted by Dept. Water well contractors are required to submit the well drilling log to DNR. |
| Alaska | Abandonment | Abandonment - General |
Shall use a method that conforms to ANSI/AWWA Standard A100-97, Water Wells, and Appendix H to ANSI/AWWA Standard A100-97 (Decommissioning of Test Holes, Partially Completed Wells, and Abandoned Completed Wells), adopted by reference in 18 AAC 80.010(b); or an alternate method that has been presented to and approved by the department. |
| Alaska | Vents | Vents - General |
No Standard Specified. |
| Alaska | Testing | Testing - General |
No Standard Specified. |
| Alaska | Seals | Seals - General |
The well must be sealed with a sanitary seal with access to monitor static water level. |
| Alaska | Screens | Screens - General |
No Standard Specified. |
| Alaska | Pumps | Pumps - General |
No Standard Specified. |
| Alaska | Pitless Adapters | Pitless Adapters - General |
No Standard Specified. |
| Alaska | Permitting | Permitting - General |
No Standard Specified. |
| Alaska | Packers | Packers - General |
No Standard Specified. |
| Alaska | Location | Wastewater System, Cleanout |
100 ft. minimum separation distance, includes domestic wastewater treatment works, onsite disposal system, and pit privy. The Dept. has the discretion to require a greater separation distance. |
| Alaska | Location | Septic Tank, Sewer Manhole |
100 ft. minimum separation distance, includes lift station and sewer cleanout. The Dept. has the discretion to require a greater separation distance. |
| Alaska | Location | Petroleum Lines, Storage Tanks |
25 ft. minimum separation distance, drinking water treatment wastes, such as backwash water from filters and water softeners and reject water from reverse osmosis units. For exceptions see Alaska Admin Code 18 AAC 72.020. Separation distances. The Dept. has the discretion to require a greater separation distance. |
| Alaska | Location | Community Sewer Line |
75 ft. minimum separation distance. The Dept. has the discretion to require a greater separation distance. |
| Alaska | Location | Sanitary Landfill, Holding Tank |
75 ft. minimum separation distance, includes industrial discharge line, or other potential source of contamination, such as domestic animal or agricultural waste. The Dept. has the discretion to require a greater separation distance. |
| Arizona | Casing | Steel |
Shall be in new or like-new condition. Shall conform to ASTM A53-89a (1989), A139-89b (1989), or A312/A312M-89a (1989). |
| Arizona | Casing | Casing - General |
May be terminated below ground level when installing a pitless adapter. Must be able to hold borehole open & survive grouting. Must be watertight. Must extend at least 1 ft. above ground level. Shall use steel or thermoplastic unless variance is obtained. Casing made of, or which has been exposed to, hazardous or potentially harmful materials, such as asbestos, shall not be used. Minimum length of casing shall be 20 ft. |
| Arizona | Caps | Caps - General |
Must make cap tamper resistant. Must notify Dept. within 5 days after capping well. |
| Arizona | Blasting | Blasting - General |
No Standard Specified. |
| Arizona | Access Ports & Tubes | Access Ports & Tubes - General |
Needed for wells with casing 4 in. or > in diameter. Port min. diameter to be 1/2 in. If a gravel tube is installed, it shall be sealed with a cap. |
| Arizona | Abandonment | Abandonment - General |
Must file notice of intent. To be performed only by licensed well drilling contractor or a property owner who has obtained a single well license from ADWR. The well, which includes the annular space outside the casing, shall be filled from the bottom to a depth of 20 feet with cement grout, concrete, bentonite, clean sand with bentonite or cuttings from the well. A cement grout plug shall be set from the top of the well to minimum of 20 feet below the land surface and the annular space outside the casing (if applicable) shall be filled with cement from the land surface to a minimum of 20 feet below the surface. Materials containing organic or toxic matter shall not be used in the abandonment of a well. ADWR must be notified in writing no later than 30 days after abandonment has been completed. The notification shall include the well owner’s name, the location of the well, and the method of abandonment. |
| Arizona | Screens | Screens - General |
No Standard Specified. |
| Arizona | Pumps | Pumps - General |
No Standard Specified. |
| Arizona | Pitless Adapters | Pitless Adapters - General |
No Standard Specified. |
| Arizona | Permitting | Permitting - General |
Must file notice of intention to drill. |
| Arizona | Packers | Packers - General |
No Standard Specified. |
| Arizona | Location | Wastewater System, Cleanout |
100 ft. |
| Arizona | Location | Septic Tank, Sewer Manhole |
100 ft. |
| Arizona | Location | Petroleum Lines, Storage Tanks |
100 ft. |
| Arizona | Location | Landfill |
100 ft. |
| Arizona | Location | Hazardous Facility Or Wastes |
100 ft. |
| Arizona | Location | Community Sewer Line |
100 ft. |
| Arizona | Location | Cess Pool |
100 ft. |
| Arizona | Licensing | Licensing - General |
Must pass an exam & be a licensed well driller. |
| Arizona | Grout | Grout - General |
Minimum standard of 1.5 inches of cement grout poured in the space between the borehole wall and the casing in one continuous application from a minimum depth of 20 feet to the land surface. |
| Arizona | Gravel/Sand-Packed Wells | Gravel/Sand-Packed Wells - General |
If installed, annular space between outer and inner casing shall be sealed. Either by welding a cap at the top or by filling with cement grout from the bottom of the outer casing to the surface. If a gravel tube is installed, it shall be sealed with a cap. |
| Arizona | Disinfection | Disinfection - General |
To disinfect a well, chlorine must be added. Various methods can be used to do this, but the concentration of chlorine in the well should be at least 50 milligrams per liter. |
| Arizona | Development | Development - General |
No Standard Specified. |
| Arizona | Cleaning | Cleaning - General |
No Standard Specified. |
| Arizona | Casing | Thermoplastic |
Shall conform to ASTM Standard F480-89 (1989). To be installed only in an oversized drillhole without driving. Rivets or screws used in the casing joints shall not penetrate the inside of the casing. |
| Arizona | Vents | Vents - General |
Shall open downward & be screened. |
| Arizona | Testing | Testing - General |
No Standard Specified. |
| Arizona | Seals | Seals - General |
Annular space to be sealed. Cement grout will be applied continuously from bottom of zone to be grouted. Cement grout may terminate at bottom of pitless adapter. Minimum length of surface seal shall be 20 ft. One ft. will extend above ground level. Surface seal shall consist of steel casing. |
| Arizona | Location | Spacing | |
| Arizona | Location | Spacing |
See well spacing well rules R12-15-1302 through R12-15-1307. |
| Arizona | Construction | Horizontal Well |
Shall be constructed with a surface seal consisting of steel casing and cement grout extending a minimum of ten ft into the land surface. |
| Arizona | Construction | Hand-dug Well |
Shall have watertight curbing extending at minimum 1 ft. above surface down to static water level, or into confining formation if well is artesian. Curbing shall consist of poured cement grout with a minimum thickness of 6 in., or casing with cement grout within a minimum of 3 in. annular space, concrete block with grout, or rock with cement grout may also be used. Must be sealed at the surface with a watertight, tamper-resistant cover. |
| Arizona | Construction | Jetting or Driving |
Shall have cement grout placed in the annular space to a minimum depth of six ft. Minimum annular space between the casing and the borehole for placement of the grout shall be 1&1/2 in. |
| Arizona | Construction | Artesian Well |
Well casing shall extend into the confining formation immediately overlying the artesian aquifer and shall be grouted from a minimum of 10 ft. into the confining formation to the land surface. If the well flows at land surface, it shall be equipped with a control valve, or means of completely controlling the flow, and be available for inspection at all times. If leaks occur adjacent to the well or around the well casing, within 30 days the well shall be completed with the seals, packers, or casing and grouting necessary to eliminate such leakage or the well shall be abandoned according to R12-15-816. |
| Arizona | Casing | Inner Casing |
Annular space between the casings shall be completely sealed by packers, casing swedging, pressure grouting or other methods which will prevent the movement of water between the casings. |
| Arkansas | Casing | Joints |
Shall be watertight welded or threaded couplings. |
| Arkansas | Casing | Fiberglass |
To be tested in accordance with ASTM D1180, pipes must have a minimum bursting pressure of 660 PSI, and couplings will have watertight seals. |
| Arkansas | Casing | Casing - General |
Grouting guides to be welded to casing. Temporary casing shall be of sufficient strength to prevent rupture. Must be watertight and permit installation without distortion or rupture. |
| Arkansas | Caps | Caps - General |
Shall be securely capped and sufficiently tight to prohibit foreign objects and insects or other creatures from entering well, and unauthorized persons without tools or excessive physical exertion. Shall be installed immediately upon completion, if pump installed, shall be capped after pump installation. |
| Arkansas | Blasting | Blasting - General |
No Standard Specified. |
| Arkansas | Additional Requirements | Additional Requirements - General |
Casing and bore hole shall be plumb and aligned. Construction reports to be filed for test holes. Construction water shall not result in contamination of well. Each well shall be tested for yield and draw down. Test holes to be plugged. Water well systems report to be filed for pumping eqpmt. |
| Arkansas | Abandonment | Abandonment - General |
Abandoned wells in consolidated formations shall be plugged for 50ft below the bottom of casing to a minimum depth of 100 ft below land surface, and remaining depth to be filled with clean sand or pea gravel. If more than one major aquifer, must have minimum seal of 50ft within each confining unit between aquifers, and between aquifer and surface. Wells in unconsolidated formations to be filled with sand or natural material to 12 ft. of surface, then filled with bentonite or cement from 12ft to 2ft. Abandoned well with no formation information is to be filled from bottom to 2 ft. of top with cement. Should be reported by the water well contractor to the AWWCC on a well abandonment form to be approved by the AWWCC within ninety (90) days of abandonment. |
| Arkansas | Location | Location - General |
Casing shall not terminate in basement of any building. Locations subject to flooding to be avoided. Well to be on ground higher than source of contamination. Shall have ready access for repairs, maintenance, treatment and inspection. The lack of specific distances for other possible sources of contamination such as streams, refuse disposal sites, excavations, waste treatment facilities, buried oil and gasoline storage tanks, improperly constructed wells and cisterns, etc. does not minimize their potential hazard. These must be evaluated in each particular situation. When the upper formations are more pervious, the lateral distances shall be increased (i.e., double the distance for highly pervious gravel formations). |
| Arkansas | Location | Leaching Pit |
100 ft. |